Spray Foam – Explained

Spray foam insulation is an alternative to traditional building insulation such as fiberglass. A two-component mixture composed of isocyanate and polyol resin comes together at the tip of a gun, and forms an expanding foam that is sprayed onto roof tiles, concrete slabs, into wall cavities, or through holes drilled in into a cavity of a finished wall.

Spray polyurethane foam (SPF) is the ideal method for insulating commercial and residential buildings. Spray foam stops air and moisture intrusion, cuts energy bills,strengths the structure, and protects the internal air from mold, airborne pollutants, and allergens, thereby creating healthy buildings.

Spray foam insulation can be categorized into two different types: open cell and closed cell.

Open cell foam insulation

Open cell, also generally referred to as 1/2 lb foam (weighing 1/2 lb per cubic foot) is a type of foam where the tiny cells are not completely closed. Open cell is less expensive because it uses fewer chemicals. It is a very good air barrier but does not provide any type of water vapor barrier. It is much more sponge-like in appearance. It is often used for interior walls because it provides sound reduction. It is not recommended for outdoor applications.

Closed cell foam insulation

Closed cell foam insulation, also generally referred to as 2 lb foam (weighing 2 lbs per cubic foot) is much denser than open cell. It has a smaller, more compact cell structure. It is a very good air barrier as well as a water vapor barrier. It is often used in roofing projects or other outdoor applications, but can be used anywhere in the home.

Open cell vs closed cell

The advantages of closed-cell foam compared to open-cell foam include its strength, higher R-value, and its greater resistance to the leakage of air or water vapor. The disadvantage of the closed-cell foam is that it is denser, requires more material, and therefore, is more expensive. Even though it has a better R-value, typically the cost per R is still higher than open-cell foam. The choice of foam can also be based on the requirements for the other performance or application specific characteristics such as strength, vapor control, available space, etc.  Open-cell SPF has an R-value around 3.5 per inch and typically uses water as the blowing agent.  Closed-cell SPF has an R-value of around 6.0 per inch (aged R-value) and uses high R-value blowing agents.

Both types of foam are commonly used in most building applications and the choice for which to use can depend on many of the factors discussed above. Some foams are inappropriate in specific applications. For example, you typically would not use open-cell foam below grade or in flotation applications where it could absorb water; this would negate its thermal performance because water is a poor insulator compared to air. Closed-cell foam would be a good choice where small framing sizes need the greatest R-value per inch possible. Closed-cell foam would be used for roofing applications.